D P L
Level transmitter XPT135
technical parameter
■ range (FS): 1 2 5 10 20 50 100 200mH20
■ Allow overpressure: 2 times the full range pressure
■ Linear error: 0.2%FS (general); 0.5%FS (max)
■ stability error:
Range> 20mH2O 0.2%FS (general); 0.5%FS (max)
Range: 20mH2O 10mmH2O (general); 20 mmH2O (maximum)
■ temperature drift:
Zero-point drift,%FS / ℃ sensitivity drift,%/℃
Range of> 10 mH2O
0.005 (General), 0.01 (max) 0.02 (max)
Range of 10 mH2O
0.01 (General), 0.02 (max.) 0.02 (max.)
Range of 5 mH2O
0.015 (General), 0.03 (max) 0.02 (max)
Range of 2 mH2O
0.025 (General), 0.05 (max) 0.02 (max)
■ service temperature range: -10~80℃;
■ Storage temperature range: -40~120℃
■ transmission mode: the second line
■ power supply pressure: 15~28VDC
■ Output number: 4~20mADC
■ load (Ω): <(u-12V)/0.02A