Digital regulator  EN6000B1


The ◆ is rich in input signals
Thermoresistance (Pt-100, Cu-100, Cu-50), thermocouple (S, B, T, R, K, E, J, N, Wre), voltage (-20~20mVDC, -100~100mVDC, 0~500mVDC, 0~1VDC, 0~5VDC, 0~10VDC), current (0~10mA, 4~20mA), etc., can also customize the input signals to process almost all industrial field signals.
◆ advanced self-tuning intelligent PID control
The setting of conventional instrument PID parameters is a very complicated process, and prone to disturbance, overshoot or undershoot. The regulator adopts self-setting algorithm to automatically adjust the * good adjustment parameters of the control process, which eliminates the tedious manual adjustment process. Intelligent PID algorithm automatically identifies and adjusts the control mode according to the characteristics of the accused object, easy to realize the excellent quality of no overshoot, no default and fast disturbance.
The ◆ has a perfect program control function
A total of 128 program control curves, The lifting and lowering temperature control of any slope can be achieved, Each curve can select different control parameters, There were 8 groups of PID groups, Eight sets of output limits correspond to 8 different overshoot suppression parameters, Proprogrammable / operational commands such as jump, run, pause and stop, And allow the program to be modified at any time during the control and operation of the program; Processing mode for outage / startup events, To fully solve the impact of unexpected power failure on the program control; Run / pause / stop operations can be performed by an external switch, Realize chain, synchronous start and operation and other functions, Convenient for manual operation; 4 Program signal output, Can be used to connect to other devices, With optional measurement startup and program waiting functions, Make the program execution more efficient and more perfect.
◆ flexible alarm, transmission function
The alarm types include: upper limit alarm, lower limit alarm, upper deviation alarm, lower deviation alarm, internal deviation alarm, external deviation alarm, overrange alarm, etc., and the standby alarm function can be set.
The transmission signal can be set by 0~10mA, 4~20mA, 0~20mA signal, PV, SV, OP1, OP2 or valve position opening transmission can be selected